Data collectionData were obtained from medical records. All the patien terjemahan - Data collectionData were obtained from medical records. All the patien Bahasa Indonesia Bagaimana mengatakan

Data collectionData were obtained f

Data collection

Data were obtained from medical records. All the patients were stable at the moment of blood samples collection, as none of them were receiving heparin, diuretics or suffering from acute illness, which might influence the accuracy of thyroid hormone assay. The levels of FT3, FT4, TSH, anti-thyroglobulin antibody (anti-TG) and anti-thyroid peroxidase antibody (anti- TPO) were measured by using an electrochemiluminescence immunoassay (Elecsys 2010, Roche, Basel, Switzerland) with intra- and inter-assay coefficients of variation of less than 5%. The laboratory reference ranges for TSH, FT4, and FT3 were 0.27-4.2 mIU/L, 12- 22 pmol/L, and 3.1-6.8 pmol/L, respectively. The lipid profile, fasting blood glucose (FBG) and uric acid (UA) level were measured using an automatic biochemistry analyser (OLYMPUS AU5400, Olympus, Japan) and
0/5000
Dari: -
Ke: -
Hasil (Bahasa Indonesia) 1: [Salinan]
Disalin!
Data collectionData were obtained from medical records. All the patients were stable at the moment of blood samples collection, as none of them were receiving heparin, diuretics or suffering from acute illness, which might influence the accuracy of thyroid hormone assay. The levels of FT3, FT4, TSH, anti-thyroglobulin antibody (anti-TG) and anti-thyroid peroxidase antibody (anti- TPO) were measured by using an electrochemiluminescence immunoassay (Elecsys 2010, Roche, Basel, Switzerland) with intra- and inter-assay coefficients of variation of less than 5%. The laboratory reference ranges for TSH, FT4, and FT3 were 0.27-4.2 mIU/L, 12- 22 pmol/L, and 3.1-6.8 pmol/L, respectively. The lipid profile, fasting blood glucose (FBG) and uric acid (UA) level were measured using an automatic biochemistry analyser (OLYMPUS AU5400, Olympus, Japan) and
Sedang diterjemahkan, harap tunggu..
Hasil (Bahasa Indonesia) 2:[Salinan]
Disalin!
Pengumpulan data Data diperoleh dari catatan medis. Semua pasien yang stabil pada saat pengumpulan sampel darah, karena tidak ada dari mereka yang menerima heparin, diuretik atau menderita penyakit akut, yang dapat mempengaruhi keakuratan tes hormon tiroid. Tingkat FT3, FT4, TSH, antibodi anti-tiroglobulin (anti-TG) dan peroksidase antibodi anti-tiroid (anti TPO) diukur dengan menggunakan immunoassay electrochemiluminescence (Elecsys 2010, Roche, Basel, Swiss) dengan intra dan koefisien antar-assay variasi kurang dari 5%. Rentang referensi laboratorium untuk TSH, FT4, dan FT3 yang 0,27-4,2 mIU / L, 12- 22 pmol / L, dan 3,1-6,8 pmol / L, masing-masing. Profil lipid, glukosa darah puasa (GDP) dan asam urat (UA) tingkat diukur dengan menggunakan analisa biokimia otomatis (OLYMPUS AU5400, Olympus, Jepang) dan

Sedang diterjemahkan, harap tunggu..
 
Bahasa lainnya
Dukungan alat penerjemahan: Afrikans, Albania, Amhara, Arab, Armenia, Azerbaijan, Bahasa Indonesia, Basque, Belanda, Belarussia, Bengali, Bosnia, Bulgaria, Burma, Cebuano, Ceko, Chichewa, China, Cina Tradisional, Denmark, Deteksi bahasa, Esperanto, Estonia, Farsi, Finlandia, Frisia, Gaelig, Gaelik Skotlandia, Galisia, Georgia, Gujarati, Hausa, Hawaii, Hindi, Hmong, Ibrani, Igbo, Inggris, Islan, Italia, Jawa, Jepang, Jerman, Kannada, Katala, Kazak, Khmer, Kinyarwanda, Kirghiz, Klingon, Korea, Korsika, Kreol Haiti, Kroat, Kurdi, Laos, Latin, Latvia, Lituania, Luksemburg, Magyar, Makedonia, Malagasi, Malayalam, Malta, Maori, Marathi, Melayu, Mongol, Nepal, Norsk, Odia (Oriya), Pashto, Polandia, Portugis, Prancis, Punjabi, Rumania, Rusia, Samoa, Serb, Sesotho, Shona, Sindhi, Sinhala, Slovakia, Slovenia, Somali, Spanyol, Sunda, Swahili, Swensk, Tagalog, Tajik, Tamil, Tatar, Telugu, Thai, Turki, Turkmen, Ukraina, Urdu, Uyghur, Uzbek, Vietnam, Wales, Xhosa, Yiddi, Yoruba, Yunani, Zulu, Bahasa terjemahan.

Copyright ©2024 I Love Translation. All reserved.

E-mail: