Flow Meter Selection * Select: Turbine (T), PD Meter (PD), Coriolis (C), Ultrasonic (UFM), Diff. Pres. (DP). If DP, state if 1, 2, or 3 DP transmitters per meter run)
Smart Multi-Variable (DP, SP, T) Select: Rosemount 3095FB Modbus
(SV), or Honeywell SMV 3000 (HV). Application 21/25 & 23/27 only.
Coriolis Mass or Volume Pulse Select: Volume pulse (V), or Mass pulse (M). Assumes (C) was selected above.
Dual Pulse Fidelity Required? Select: Yes (Y), or No (N). Note: Assumes a suitably-equipped flow meter.
Gas UFM Serial Communications Select: Yes (Y), or No (N). Assumes a compatible communications protocol is available.
Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), HART
(H), or Honeywell DE (DE).
Pressure Select: 4-20mA (mA), 1-5Volts (V), HART (H), or Honeywell DE (DE).
Densitometer Select: 4-20mA (mA), 1-5Volts (V), or Frequency (F).
Density Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD
(RTD), or HART (H).
Density Pressure Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H).
Additional Analog Inputs (BS&W, CO2, N2, O2 etc.) Select number and signal type: 4-20mA (mA), 1-5Volts (V), or HART (H).
Gas Chromatograph Select: RS232 (232), or RS485 (485).
*Note: Combination of Turbine and Differential Pressure inputs is only available on Rev. 23 and 27.
Prover Configurations Peripheral I/O
Dual chronometry Proving? Select: Yes (Y), or No
(N). Digital I/O Points Required
Maximum 24
Plenum Pressure Select: 4-20mA (mA), 1-5Volts
(V), 4 wire RTD (RTD), or HART (H). 4-20 mA outputs Required
(Maximum 18)
Switch Bar Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H). Serial Ports Required
(Maximum 6 for 6000 and 2 for 3000)
Prover Inlet Temperature Select: 4-20mA
(mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H). Ethernet Ports Required
(Maximum 2 for 6000 and 1 for 3000)
Prover Outlet Temperature Select: 4-20mA
(mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H).
Prover Inlet Pressure Select: 4-20mA (mA), 1- 5Volts (V), or HART (H).
Prover Outlet Pressure Select: 4-20mA (mA), 1- 5Volts (V), or HART (H).
Prover Densitometer Select: 4-20mA (mA), 1- 5Volts (V), or Frequency (F).
Model Number: Qty:
Flow Meter Brand:
Approval Requirements (e.g.; OIML, local):
Comments:
Hasil (
Bahasa Indonesia) 1:
[Salinan]Disalin!
Flow Meter pilihan * Pilih: turbin (T), PD Meter (PD), Coriolis (C), ultrasonik (UFM), Diff. Pres. (DP). Jika menjalankan DP, negara jika 1, 2, atau 3 DP pemancar per meter) Pilih cerdas multi variabel (DP, SP, T): Rosemount 3095FB Modbus(SV), atau Honeywell SMV 3000 (HV). Aplikasi 21/25 & hanya 23/27. Coriolis massa atau Volume Pulse Pilih: Volume pulsa (V), atau massa pulsa (M). Mengasumsikan (C) Terpilih di atas. Dual Pulse kesetiaan diperlukan? Pilih: Ya (Y), atau tidak (N). Catatan: Mengasumsikan sesuai-dilengkapi flow meter. Gas UFM komunikasi Serial Pilih: Ya (Y), atau tidak (N). Menganggap protokol komunikasi kompatibel tersedia. Pilih suhu: 4-20mA (mA), 1-5Volts (V), 4 kawat RTD (RTD), HART(H), atau Honeywell DE (DE). Tekanan Pilih: 4-20mA (mA), 1-5Volts (V), HART (H) atau Honeywell DE (DE). Pilih DENSITOMETER: 4-20mA (mA), 1-5Volts (V) atau frekuensi (F). Pilih kepadatan suhu: 4-20mA (mA), 1-5Volts (V), 4 kawat RTD(RTD), atau HART (H). Pilih kepadatan tekanan: 4-20mA (mA), 1-5Volts (V), 4 kawat RTD (RTD) atau HART (H). Tambahan input Analog (BS & W, CO2, N2, O2 dll.) Pilih jenis nomor dan sinyal: 4-20mA (mA), 1-5Volts (V) atau HART (H). Pilih gas Chromatograph: RS232 (232), atau RS485 (485). * Catatan: Kombinasi input turbin dan tekanan diferensial ini hanya tersedia pada tanggal 23 Wahyu dan 27.Prover konfigurasi I/O periferCatatan waktu dual membuktikan? Pilih: Ya (Y), atau tidak(N). Digital i/o poin diperlukanMaksimum 24 Sidang Pleno tekanan Pilih: 4-20mA (mA), 1-5Volts(V), 4 kawat RTD (RTD) atau HART (H). 4-20 mA output diperlukan(Maksimal 18) Pilih suhu switch Bar: 4-20mA (mA), 1-5Volts (V), 4 kawat RTD (RTD) atau HART (H). Port serial yang diperlukan(Maksimal 6 untuk 6000 dan 2 untuk 3000) Prover Inlet suhu Pilih: 4-20mA(mA), 1-5Volts (V), 4 kawat RTD (RTD) atau HART (H). Port Ethernet diperlukan(Maksimal 2 untuk 6000 dan 1 untuk 3000) Pilih prover Outlet suhu: 4-20mA(mA), 1-5Volts (V), 4 kawat RTD (RTD) atau HART (H). Prover Inlet tekanan Pilih: 4-20mA (mA), 1-5Volts (V) atau HART (H). Prover Outlet tekanan Pilih: 4-20mA (mA), 1-5Volts (V) atau HART (H). Pilih prover Densitometer: 4-20mA (mA), 1-5Volts (V) atau frekuensi (F). Nomor model: Qty: Flow Meter merk: Persetujuan persyaratan (misalnya; OIML, lokal): Komentar: