Flow Meter Selection * Select: Turbine (T), PD Meter (PD), Coriolis (C terjemahan - Flow Meter Selection * Select: Turbine (T), PD Meter (PD), Coriolis (C Bahasa Indonesia Bagaimana mengatakan

Flow Meter Selection * Select: Turb

Flow Meter Selection * Select: Turbine (T), PD Meter (PD), Coriolis (C), Ultrasonic (UFM), Diff. Pres. (DP). If DP, state if 1, 2, or 3 DP transmitters per meter run)
Smart Multi-Variable (DP, SP, T) Select: Rosemount 3095FB Modbus
(SV), or Honeywell SMV 3000 (HV). Application 21/25 & 23/27 only.
Coriolis Mass or Volume Pulse Select: Volume pulse (V), or Mass pulse (M). Assumes (C) was selected above.
Dual Pulse Fidelity Required? Select: Yes (Y), or No (N). Note: Assumes a suitably-equipped flow meter.
Gas UFM Serial Communications Select: Yes (Y), or No (N). Assumes a compatible communications protocol is available.
Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), HART
(H), or Honeywell DE (DE).
Pressure Select: 4-20mA (mA), 1-5Volts (V), HART (H), or Honeywell DE (DE).
Densitometer Select: 4-20mA (mA), 1-5Volts (V), or Frequency (F).
Density Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD
(RTD), or HART (H).
Density Pressure Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H).
Additional Analog Inputs (BS&W, CO2, N2, O2 etc.) Select number and signal type: 4-20mA (mA), 1-5Volts (V), or HART (H).
Gas Chromatograph Select: RS232 (232), or RS485 (485).
*Note: Combination of Turbine and Differential Pressure inputs is only available on Rev. 23 and 27.
Prover Configurations Peripheral I/O
Dual chronometry Proving? Select: Yes (Y), or No
(N). Digital I/O Points Required
Maximum 24
Plenum Pressure Select: 4-20mA (mA), 1-5Volts
(V), 4 wire RTD (RTD), or HART (H). 4-20 mA outputs Required
(Maximum 18)
Switch Bar Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H). Serial Ports Required
(Maximum 6 for 6000 and 2 for 3000)
Prover Inlet Temperature Select: 4-20mA
(mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H). Ethernet Ports Required
(Maximum 2 for 6000 and 1 for 3000)
Prover Outlet Temperature Select: 4-20mA
(mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H).
Prover Inlet Pressure Select: 4-20mA (mA), 1- 5Volts (V), or HART (H).
Prover Outlet Pressure Select: 4-20mA (mA), 1- 5Volts (V), or HART (H).
Prover Densitometer Select: 4-20mA (mA), 1- 5Volts (V), or Frequency (F).
Model Number: Qty:
Flow Meter Brand:
Approval Requirements (e.g.; OIML, local):
Comments:
0/5000
Dari: -
Ke: -
Hasil (Bahasa Indonesia) 1: [Salinan]
Disalin!
Flow Meter Selection * Select: Turbine (T), PD Meter (PD), Coriolis (C), Ultrasonic (UFM), Diff. Pres. (DP). If DP, state if 1, 2, or 3 DP transmitters per meter run) Smart Multi-Variable (DP, SP, T) Select: Rosemount 3095FB Modbus(SV), or Honeywell SMV 3000 (HV). Application 21/25 & 23/27 only. Coriolis Mass or Volume Pulse Select: Volume pulse (V), or Mass pulse (M). Assumes (C) was selected above. Dual Pulse Fidelity Required? Select: Yes (Y), or No (N). Note: Assumes a suitably-equipped flow meter. Gas UFM Serial Communications Select: Yes (Y), or No (N). Assumes a compatible communications protocol is available. Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), HART(H), or Honeywell DE (DE). Pressure Select: 4-20mA (mA), 1-5Volts (V), HART (H), or Honeywell DE (DE). Densitometer Select: 4-20mA (mA), 1-5Volts (V), or Frequency (F). Density Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD(RTD), or HART (H). Density Pressure Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H). Additional Analog Inputs (BS&W, CO2, N2, O2 etc.) Select number and signal type: 4-20mA (mA), 1-5Volts (V), or HART (H). Gas Chromatograph Select: RS232 (232), or RS485 (485). *Note: Combination of Turbine and Differential Pressure inputs is only available on Rev. 23 and 27.Prover Configurations Peripheral I/ODual chronometry Proving? Select: Yes (Y), or No(N). Digital I/O Points RequiredMaximum 24 Plenum Pressure Select: 4-20mA (mA), 1-5Volts(V), 4 wire RTD (RTD), or HART (H). 4-20 mA outputs Required(Maximum 18) Switch Bar Temperature Select: 4-20mA (mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H). Serial Ports Required(Maximum 6 for 6000 and 2 for 3000) Prover Inlet Temperature Select: 4-20mA(mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H). Ethernet Ports Required(Maximum 2 for 6000 and 1 for 3000) Prover Outlet Temperature Select: 4-20mA(mA), 1-5Volts (V), 4 wire RTD (RTD), or HART (H). Prover Inlet Pressure Select: 4-20mA (mA), 1- 5Volts (V), or HART (H). Prover Outlet Pressure Select: 4-20mA (mA), 1- 5Volts (V), or HART (H). Prover Densitometer Select: 4-20mA (mA), 1- 5Volts (V), or Frequency (F). Model Number: Qty: Flow Meter Brand: Approval Requirements (e.g.; OIML, local): Comments:
Sedang diterjemahkan, harap tunggu..
Hasil (Bahasa Indonesia) 2:[Salinan]
Disalin!
Flow Meter Seleksi * Pilih: Turbine (T), PD Meter (PD), Coriolis (C), Ultrasonic (UFM), Diff. Pres. (DP). Jika DP, negara jika 1, 2, atau 3 DP pemancar per meter lari)
Cerdas Multi-Variable (DP, SP, T) Pilih: Rosemount 3095FB Modbus
(SV), atau Honeywell SMV 3000 (HV). . Aplikasi 21/25 & 23/27 hanya
Coriolis Mass atau Volume Pulse Pilih: pulsa Volume (V), atau pulsa Mass (M). Mengasumsikan (C) terpilih di atas.
Ganda Pulse Fidelity Diperlukan? Pilih: Ya (Y), atau ada (N). Catatan:. Menganggap flow meter sesuai dilengkapi
Gas UFM Serial Komunikasi Pilih: Ya (Y), atau ada (N). Mengasumsikan protokol komunikasi yang kompatibel tersedia.
Suhu Pilih: 4-20mA (mA), 1-5Volts (V), 4 kawat RTD (RTD), HART
. (H), atau Honeywell DE (DE)
Tekanan Pilih: 4-20mA (mA), 1-5Volts (V), HART (H), atau Honeywell DE (DE).
Densitometer Pilih: 4-20mA (mA), 1-5Volts (V), atau Frekuensi (F).
Kepadatan Suhu Pilih: 4-20mA (mA), 1-5Volts (V), 4 kawat RTD
(RTD), atau HART (H).
Kepadatan Tekanan Pilih: 4-20mA (mA), 1-5Volts (V), 4 kawat RTD (RTD ), atau HART (H).
Tambahan Analog Input (BS & W, CO2, N2, O2 dll) Pilih jumlah dan jenis sinyal: 4-20mA (mA), 1-5Volts (V), atau HART (H).
Gas Kromatografi Pilih: RS232 (232), atau RS485 (485).
* Catatan: Kombinasi Turbin dan Tekanan Diferensial input hanya tersedia pada Wahyu 23 dan 27.
prover Konfigurasi Peripheral I / O
Ganda chronometry Membuktikan? Pilih: Ya (Y), atau ada
(N). Digital I / O Tempat yang harus diisi
maksimum 24
Pleno Tekanan Pilih: 4-20mA (mA), 1-5Volts
(V), 4 kawat RTD (RTD), atau HART (H). 4-20 output mA Diperlukan
(maksimum 18)
Beralih Bar Suhu Pilih: 4-20mA (mA), 1-5Volts (V), 4 kawat RTD (RTD), atau HART (H). Serial Ports Diperlukan
(maksimum 6 untuk 6000 dan 2 untuk 3000)
prover Inlet Suhu Pilih: 4-20mA
(mA), 1-5Volts (V), 4 kawat RTD (RTD), atau HART (H). Port Ethernet Diperlukan
(maksimum 2 untuk 6000 dan 1 untuk 3000)
Pilih prover Outlet Suhu: 4-20mA
. (mA), 1-5Volts (V), 4 kawat RTD (RTD), atau HART (H)
prover Inlet Pressure Pilih: 4-20mA (mA), 1- 5Volts (V), atau HART (H).
prover Outlet Tekanan Pilih: 4-20mA (mA), 1- 5Volts (V), atau HART (H).
prover Densitometer Pilih: 4 . -20mA (mA), 1- 5Volts (V), atau Frekuensi (F)
Nomor model: Qty:
Flow Meter Merek:
Persyaratan Persetujuan (misalnya; OIML, lokal):
Komentar:
Sedang diterjemahkan, harap tunggu..
 
Bahasa lainnya
Dukungan alat penerjemahan: Afrikans, Albania, Amhara, Arab, Armenia, Azerbaijan, Bahasa Indonesia, Basque, Belanda, Belarussia, Bengali, Bosnia, Bulgaria, Burma, Cebuano, Ceko, Chichewa, China, Cina Tradisional, Denmark, Deteksi bahasa, Esperanto, Estonia, Farsi, Finlandia, Frisia, Gaelig, Gaelik Skotlandia, Galisia, Georgia, Gujarati, Hausa, Hawaii, Hindi, Hmong, Ibrani, Igbo, Inggris, Islan, Italia, Jawa, Jepang, Jerman, Kannada, Katala, Kazak, Khmer, Kinyarwanda, Kirghiz, Klingon, Korea, Korsika, Kreol Haiti, Kroat, Kurdi, Laos, Latin, Latvia, Lituania, Luksemburg, Magyar, Makedonia, Malagasi, Malayalam, Malta, Maori, Marathi, Melayu, Mongol, Nepal, Norsk, Odia (Oriya), Pashto, Polandia, Portugis, Prancis, Punjabi, Rumania, Rusia, Samoa, Serb, Sesotho, Shona, Sindhi, Sinhala, Slovakia, Slovenia, Somali, Spanyol, Sunda, Swahili, Swensk, Tagalog, Tajik, Tamil, Tatar, Telugu, Thai, Turki, Turkmen, Ukraina, Urdu, Uyghur, Uzbek, Vietnam, Wales, Xhosa, Yiddi, Yoruba, Yunani, Zulu, Bahasa terjemahan.

Copyright ©2024 I Love Translation. All reserved.

E-mail: